White & Orange Stripe
Showing all 14 results
-
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 Wire
UL 1007/1569 20 AWG 10 Strand 105C 300V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 WireUL 1007/1569 20 AWG 10 Strand 105C 300V – Tinned Copper
UL 1007 20 AWG pvc insulated wire is constructed with solid or stranded tinned copper conductors and a pvc insulation with acid, oil and chemical resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 300 volt rating, it’s ideal for use in appliances, computers, control panels, meters, jumper wires, transformers, turbines and generators.
Min/Mult: 100/50
SKU: W10072010-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 Wire
UL 1007/1569 22 AWG 7 Strand 105C 300V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 WireUL 1007/1569 22 AWG 7 Strand 105C 300V – Tinned Copper
UL 1007 22 AWG pvc insulated wire is constructed with solid or stranded tinned copper conductors and a pvc insulation with acid, oil and chemical resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 300 volt rating, it’s ideal for use in appliances, computers, control panels, meters, jumper wires, transformers, turbines and generators.
Min/Mult: 100/50
SKU: W10072207-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 Wire
UL 1007/1569 24 AWG 07 Strand 105C 300V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1007 WireUL 1007/1569 24 AWG 07 Strand 105C 300V – Tinned Copper
UL 1007 24 AWG pvc insulated wire is constructed with solid or stranded tinned copper conductors and a pvc insulation with acid, oil and chemical resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 300 volt rating, it’s ideal for use in appliances, computers, control panels, meters, jumper wires, transformers, turbines and generators.
Min/Mult: 100/50
SKU: W10072407-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 18 AWG 16 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 18 AWG 16 Strand 105C 600V – Tinned Copper
UL 1015 18 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10151816-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 20 AWG 10 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 20 AWG 10 Strand 105C 600V – Tinned Copper
UL 1015 20 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10152010-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 14 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 14 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 14 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14301419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 16 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 16 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 16 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14301619-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 18 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 18 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 18 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14301819-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 20 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 20 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 20 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14302019-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 22 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 22 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 22 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14302219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 18 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50