Hook-Up & Lead Wire & Cable takes care of general purpose internal wiring used in electronic equipment and appliance applications. These conductors have been rated by UL to ensure that they are not only safe to use in specific electronic and appliance equipment and devices where their is high temperatures and environments; but also to be resistant to oil and gas resistant. At National Electric USA, we offer several hook-up wire & cable options: High Temperature, High Voltage, XLPVC, ETFE, FEP, mPPE, PFA, PTFE, PVC & silicone insulated wires; with various UL ratings so you can find the right fit for your needs.
Below, you’ll find links to our UL listed hook-up & lead wire & cable followed by our categorized full selection.
Can’t find what you’re looking for?   Call us at: 562-808-0800
Hook-up & Lead Wire
Showing all 32 results
-
ETFE Hook-Up Wire, Hook-up & Lead Wire, UL 10086 Wire
UL 10086 18 AWG 07 Strand 200C 600V – Tinned Copper
ETFE Hook-Up Wire, Hook-up & Lead Wire, UL 10086 WireUL 10086 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 10086 18 AWG ETFE hook-up wire is constructed with solid or stranded, tin-plated or silver-plated copper conductors. Its tough extruded modified ethylene tetrafluoroethylene insulation makes it light and thinner, allowing it to pass the flame test. With a 600V rating and a 200°C maximum temperature but with a 150°C option available, it’s ideal for use in internal wiring of appliances, lighting systems, electrical equipment and switches.
Min/Mult: 100/50
SKU: W100861807-T -
Hook-up & Lead Wire, UL 10086 Wire
UL 10086 22 AWG 07 Strand 200C 600V – Tinned Copper
UL 10086 22 AWG ETFE hook-up wire is constructed with solid or stranded, tin-plated or silver-plated copper conductors. Its tough extruded modified ethylene tetrafluoroethylene insulation makes it light and thinner, allowing it to pass the flame test. With a 600V rating and a 200°C maximum temperature but with a 150°C option available, it’s ideal for use in internal wiring of appliances, lighting systems, electrical equipment and switches.
Min/Mult: 100/50
SKU: W100862207-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 10 AWG 105 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 10 AWG 105 Strand 105C 600V – Tinned Copper
UL 1015 10 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W101510H5-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 12 AWG 65 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 12 AWG 65 Strand 105C 600V – Tinned Copper
UL 1015 12 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10151265-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 14 AWG 41 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 14 AWG 41 Strand 105C 600V – Tinned Copper
UL 1015 14 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10151441-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 16 AWG 26 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 16 AWG 26 Strand 105C 600V – Tinned Copper
UL 1015 16 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10151626-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 18 AWG 16 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 18 AWG 16 Strand 105C 600V – Tinned Copper
UL 1015 18 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10151816-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 20 AWG 10 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 20 AWG 10 Strand 105C 600V – Tinned Copper
UL 1015 20 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10152010-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 22 AWG 07 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 22 AWG 07 Strand 105C 600V – Tinned Copper
UL 1015 22 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10152207-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 Wire
UL 1015 24 AWG 07 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1015 WireUL 1015 24 AWG 07 Strand 105C 600V – Tinned Copper
UL 1015 24 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors and a extruded thermoplastic pvc insulation with acid, oil and alkali resistance capable of passing the UL VW-1 Flame Test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in the AC, DC wiring of appliances and control panels.
Min/Mult: 100/50
SKU: W10152407-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1028 Wire
UL 1028 08 AWG 133 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1028 WireUL 1028 08 AWG 133 Strand 105C 600V – Tinned Copper
UL 1028 8 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors. It is pvc insulated with moisture resistance and capable of passing the horizontal flame test. With a 105°C maximum temperature and 300 volt rating, it’s ideal for use in appliances, machine tools, circuits and switchboards.
Min/Mult: 100/50
SKU: W102808133-T -
Hook-up & Lead Wire, UL Style 11028
UL 11028 18 AWG 16 Strand 105C 600V – Tinned Copper
UL 11028 18 AWG mPPE insulated wire is constructed with solid or stranded, tinned copper or silver plated conductors. Its extruded modified polyphenylene ether insulation allows it to pass the flame test. With a 105°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring use.
Min/Mult: 100/50
SKU: W110281816-T -
Hook-up & Lead Wire, UL Style 11028
UL 11028 28 AWG 07 Strand 105C 600V – Silver Plated
UL 11028 28 AWG mPPE insulated wire is constructed with solid or stranded, tinned copper or silver plated conductors. Its extruded modified polyphenylene ether insulation allows it to pass the flame test. With a 105°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring use.
Min/Mult: 100/50
SKU: W110282807-S -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 14 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 18 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311819-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 22 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14312219-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3071 Wire
UL 3071 14 AWG 07 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3071 WireUL 3071 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3071 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal appliance wiring.
Min/Mult: 100/50
SKU: W30711407-T -
Hook-up & Lead Wire, UL 3071 Wire
UL 3071 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 3071 18 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal appliance wiring.
Min/Mult: 100/50
SKU: W30711807-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3074 Wire
UL 3074 12 AWG 19 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3074 WireUL 3074 12 AWG 19 Strand 200C 600V – Tinned Copper
UL 3074 12 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W30741219-T -
Hook-up & Lead Wire, UL 3075 Wire
UL 3075 10 AWG 19 Strand 200C 600V – Tinned Copper
UL 3075 10 AWG silicone insulated wire is constructed with solid or stranded round, tinned, nickel or silver plated copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of dryers and appliances.
Min/Mult: 100/50
SKU: W30751019-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 Wire
UL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 WireUL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
UL 3173 18 AWG cross-linked hook-up wire is constructed with stranded, tinned or bare copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 600V rating, it’s ideal for use in control paneling, motor leads, transformers and internal wiring of appliances.
Min/Mult: 100/50
SKU: W31731816-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 16 AWG 26 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 16 AWG 26 Strand 150C 600V – Tinned Copper
UL 3321 16 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211626-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 18 AWG 16 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 18 AWG 16 Strand 150C 600V – Tinned Copper
UL 3321 18 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211816-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 20 AWG 10 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 20 AWG 10 Strand 150C 600V – Tinned Copper
UL 3321 20 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33212010-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 22 AWG 07 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 22 AWG 07 Strand 150C 600V – Tinned Copper
UL 3321 22 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33212207-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121407-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 16 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 16 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121607-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 18 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121807-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 20 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 20 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35122007-T