Hook-Up & Lead Wire & Cable takes care of general purpose internal wiring used in electronic equipment and appliance applications. These conductors have been rated by UL to ensure that they are not only safe to use in specific electronic and appliance equipment and devices where their is high temperatures and environments; but also to be resistant to oil and gas resistant. At National Electric USA, we offer several hook-up wire & cable options: High Temperature, High Voltage, XLPVC, ETFE, FEP, mPPE, PFA, PTFE, PVC & silicone insulated wires; with various UL ratings so you can find the right fit for your needs.
Below, you’ll find links to our UL listed hook-up & lead wire & cable followed by our categorized full selection.
Can’t find what you’re looking for? Call us at: 562-808-0800
Hook-up & Lead Wire
Showing all 8 results
-
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 12 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 12 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 12 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 14 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 18 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311819-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 Wire
UL 3173 16 AWG 26 Strand 125C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 WireUL 3173 16 AWG 26 Strand 125C 600V – Tinned Copper
UL 3173 16 AWG cross-linked hook-up wire is constructed with stranded, tinned or bare copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 600V rating, it’s ideal for use in control paneling, motor leads, transformers and internal wiring of appliances.
Min/Mult: 100/50
SKU: W31731626-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 Wire
UL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 WireUL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
UL 3173 18 AWG cross-linked hook-up wire is constructed with stranded, tinned or bare copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 600V rating, it’s ideal for use in control paneling, motor leads, transformers and internal wiring of appliances.
Min/Mult: 100/50
SKU: W31731816-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3512 Wire
UL 3512 08 AWG 54 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3512 WireUL 3512 08 AWG 54 Strand 200C 600V – Tinned Copper
UL 3512 8 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35120854-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121407-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 18 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121807-T