UL Style 1911 Wire
UL Style 1911 Wire Standard: UL 758
National Electric USA’s quality UL 1911 wire is part of the PFA Insulated Wire product line. It is available in a variety of colors and constructions. This wire satisfies UL 758 standards and is specifically designed for the internal wiring of electronic gas ignitor systems.
- Conductor: Solid or Stranded, Nickel Plated
- Insulation: PFA
- Rated Temperature: 250°C
- Rated Voltage: 25KV
- Flame Test: Passed Horizontal Flame Test
- Application: Internal wiring of electronic gas ignitor systems
Call us at 562-808-0800 or email [email protected] to speak with a customer service representative.
UL Style 1911
Showing all 4 results
-
Hook-up & Lead Wire, PFA Insulated Wire, UL Style 1911
UL 1911 18 AWG 19 Strand 250C 25KV – Nickel Plated
Hook-up & Lead Wire, PFA Insulated Wire, UL Style 1911UL 1911 18 AWG 19 Strand 250C 25KV – Nickel Plated
UL 1911 18 AWG PFA insulated wire is constructed with solid or stranded, nickel plated conductors. Its extruded perfluoroalkoxy insulation allows it to pass the flame test. With a 260°C maximum temperature and a rated voltage of 25KV, it’s ideal for internal wiring of electronic gas ignitor system use.
Min/Mult: 100/50
SKU: W19111819-N -
Hook-up & Lead Wire, UL Style 1911
UL 1911 20 AWG 07 Strand 250C 25KV – Nickel Plated
UL 1911 20 AWG PFA insulated wire is constructed with solid or stranded, nickel plated conductors. Its extruded perfluoroalkoxy insulation allows it to pass the flame test. With a 260°C maximum temperature and a rated voltage of 25KV, it’s ideal for internal wiring of electronic gas ignitor system use.
Min/Mult: 100/50
SKU: W19112007-N -
Hook-up & Lead Wire, UL Style 1911
UL 1911 20 AWG 19 Strand 250C 25KV – Nickel Plated
UL 1911 20 AWG PFA insulated wire is constructed with solid or stranded, nickel plated conductors. Its extruded perfluoroalkoxy insulation allows it to pass the flame test. With a 260°C maximum temperature and a rated voltage of 25KV, it’s ideal for internal wiring of electronic gas ignitor system use.
Min/Mult: 100/50
SKU: W19112019-N -
Hook-up & Lead Wire, UL Style 1911
UL 1911 22 AWG 07 Strand 250C 25KV – Nickel Plated
UL 1911 22 AWG PFA insulated wire is constructed with solid or stranded, nickel plated conductors. Its extruded perfluoroalkoxy insulation allows it to pass the flame test. With a 260°C maximum temperature and a rated voltage of 25KV, it’s ideal for internal wiring of electronic gas ignitor system use.
Min/Mult: 100/50
SKU: W19112207-N