Belden Multi-Pair Cable 1420A

BELDEN
Availability:

100 in stock


Computer EIA RS-232/422 Cable, 3-Pair, 24 AWG stranded (7×32) tinned copper conductors, Datalene® insulation, overall Beldfoil® shield (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.

$0.39 FT

100 in stock

Product Overview
Suitable Applications RS-232 extended distance applications; RS-423 applications; computer communications; low voltage analog signals (4-20ma, 0-10v, …); low voltage digital control (24v, …); line level audio; panel wiring
Construction Details
CONDUCTOR
Element Number of Element Size Stranding Material
Pair(s) 3 24 AWG 7×32 TC – Tinned Copper
INSULATION
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Pair(s) PE – Polyethylene (Foam) 0.013 in (0.33 mm) 0.049 in (1.2 mm) Western Electric Standard
OUTER SHIELD
Shield Type Material Coverage Drainwire Type
Tape Bi-Laminate (Alum+Poly) 100% 24 AWG (7×32) TC
OUTER JACKET
Material Nom. Thickness Nom. Diameter
PVC – Polyvinyl Chloride 0.035 in (0.89 mm) 0.261 in (6.63 mm)
Overall Cable Diameter (Nominal) 0.261 in (6.63 mm)
Electrical Characteristics
ELECTRICALS
Element Nom. Conductor DCR Nom. Capacitance Cond-to-Cond Nom. Capacitance Cond-to-Other (Conds + Shield) Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
Pair(s) 24 Ohm/1000ft 13 pF/ft (43 pF/m) 22 pF/ft (72 pF/m) 100 Ohm 78% 1.8 Amps per Conductor at 25ºC
VOLTAGE
UL Voltage Rating
300 V (CM), 30 V (UL AWM 2919)
Mechanical Characteristics
TEMPERATURE
UL Temperature Operating
80°C -20°C to +80°C
BEND RADIUS
Stationary Min. Installation Min.
2.6 in (66 mm) 2.6 in (66 mm)
Max. Pull Tension 33 lbs (15 kg)
Bulk Cable Weight 30 lbs/1000ft
Standards and Compliance
Environmental Suitability Indoor (Not Riser or Plenum), Indoor
Flammability / Reaction to Fire UL 1685 FT4 Loading, IEC 60332-1-2
CPR Compliance CPR Euroclass: Eca
NEC / UL Compliance Article 800, CM
AWM Compliance AWM 2919
CEC / C(UL) Compliance CM
European Directive Compliance EU CE Mark, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
UK Regulation Compliance UKCA Mark
APAC Compliance China RoHS II (GB/T 26572-2011)
Product Notes
Notes Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low distortion data handling. Physical properties include good crush resistance and light weight.
SKU: BEL-1420A Category:
Weight 0.13 lbs
Dimensions 1 × 0.125 × 0.125 in
Conductor

Insulation

Minimum Temperature Rating

Maximum Temperature Rating

Voltage Rating

Manufacturer

Manufacturer Part Number

Conductor Stranding

Conductor Count

Gauge

SHOPPING CART

close