Orange
Showing 129–146 of 146 results
-
Hook-up & Lead Wire, UL 3071 Wire
UL 3071 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 3071 18 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal appliance wiring.
Min/Mult: 100/50
SKU: W30711807-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3074 Wire
UL 3074 12 AWG 19 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3074 WireUL 3074 12 AWG 19 Strand 200C 600V – Tinned Copper
UL 3074 12 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W30741219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 Wire
UL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3173 WireUL 3173 18 AWG 16 Strand 125C 600V – Tinned Copper
UL 3173 18 AWG cross-linked hook-up wire is constructed with stranded, tinned or bare copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 600V rating, it’s ideal for use in control paneling, motor leads, transformers and internal wiring of appliances.
Min/Mult: 100/50
SKU: W31731816-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3212 Wire
UL 3212 12 AWG 65 Strand 150C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3212 WireUL 3212 12 AWG 65 Strand 150C 600V – Tinned Copper
UL 3212 12 AWG silicone insulated wire is constructed with solid or stranded round, tinned or bare copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 150°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W32121265-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3213 Wire
UL 3213 12 AWG 65 Strand 150C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3213 WireUL 3213 12 AWG 65 Strand 150C 600V – Tinned Copper
UL 3213 12 AWG silicone insulated wire is constructed with stranded round, tinned or plated copper or nickel plated conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 150°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W32131265-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3266 Wire
UL 3266 22 AWG 07 Strand 125C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3266 WireUL 3266 22 AWG 07 Strand 125C 300V – Tinned Copper
UL 3266 22 AWG cross-linked hook-up wire is constructed with stranded or solid, tinned copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 300V rating, it’s ideal for use in internal wiring of appliances, computers test, equipment, business machines and other office and control equipments.
Min/Mult: 100/50
SKU: W32662207-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3304 Wire
UL 3304 18 AWG 07 Strand 200C 1KV – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3304 WireUL 3304 18 AWG 07 Strand 200C 1KV – Tinned Copper
UL 3304 18 AWG silicone insulated wire is constructed with solid or stranded round, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 1KV, it’s ideal for internal wiring of electronic ignitions and other similar applications in gas ranges or fuel oil burner systems, appliances.
Min/Mult: 100/50
SKU: W33041807-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 10 AWG 105 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 10 AWG 105 Strand 150C 600V – Tinned Copper
UL 3321 10 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W332110H5-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 12 AWG 65 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 12 AWG 65 Strand 150C 600V – Tinned Copper
UL 3321 12 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211265-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 14 AWG 41 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 14 AWG 41 Strand 150C 600V – Tinned Copper
UL 3321 14 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211441-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 16 AWG 26 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 16 AWG 26 Strand 150C 600V – Tinned Copper
UL 3321 16 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211626-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 18 AWG 16 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 18 AWG 16 Strand 150C 600V – Tinned Copper
UL 3321 18 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211816-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 20 AWG 10 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 20 AWG 10 Strand 150C 600V – Tinned Copper
UL 3321 20 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33212010-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3512 Wire
UL 3512 08 AWG 54 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3512 WireUL 3512 08 AWG 54 Strand 200C 600V – Tinned Copper
UL 3512 8 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35120854-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121407-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 18 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 18 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121807-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 20 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 20 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35122007-T