Hook-Up & Lead Wire & Cable takes care of general purpose internal wiring used in electronic equipment and appliance applications. These conductors have been rated by UL to ensure that they are not only safe to use in specific electronic and appliance equipment and devices where their is high temperatures and environments; but also to be resistant to oil and gas resistant. At National Electric USA, we offer several hook-up wire & cable options: High Temperature, High Voltage, XLPVC, ETFE, FEP, mPPE, PFA, PTFE, PVC & silicone insulated wires; with various UL ratings so you can find the right fit for your needs.
Below, you’ll find links to our UL listed hook-up & lead wire & cable followed by our categorized full selection.
Can’t find what you’re looking for?   Call us at: 562-808-0800
Hook-up & Lead Wire
Showing all 10 results
-
Hook-up & Lead Wire, PVC Insulated Wire, UL 1283 Wire
UL 1283 04 AWG 133 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1283 WireUL 1283 04 AWG 133 Strand 105C 600V – Tinned Copper
UL 1283 4 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors. It is pvc insulated with moisture resistance and capable of passing the VW-1 flame test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in appliances, machine tools, circuits, control panels, meters and transformers.
Min/Mult: 100/50
SKU: W128304133-T -
Hook-up & Lead Wire, PVC Insulated Wire, UL 1283 Wire
UL 1283 06 AWG 133 Strand 105C 600V – Tinned Copper
Hook-up & Lead Wire, PVC Insulated Wire, UL 1283 WireUL 1283 06 AWG 133 Strand 105C 600V – Tinned Copper
UL 1283 6 AWG pvc insulated wire is constructed with solid or stranded, bare or tinned copper conductors. It is pvc insulated with moisture resistance and capable of passing the VW-1 flame test. With a 105°C maximum temperature and 600 volt rating, it’s ideal for use in appliances, machine tools, circuits, control panels, meters and transformers.
Min/Mult: 100/50
SKU: W128306133-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 12 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 12 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 12 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 14 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 18 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 18 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311819-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 22 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14312219-T -
High Voltage Hook-Up Wire, Hook-up & Lead Wire, UL Style 3239
UL 3239 16 AWG 26 Strand 200C 20KV – Tinned Copper
High Voltage Hook-Up Wire, Hook-up & Lead Wire, UL Style 3239UL 3239 16 AWG 26 Strand 200C 20KV – Tinned Copper
UL 3239 16 AWG high voltage hook-up wire is constructed with solid or stranded, tinned bare or bare copper, silver, nickel or aluminum plated conductors. Its extruded or non-extruded thermoplastic and or thermosetting insulation allows it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 20KV, it’s ideal for use in internal wiring of TV receivers, stoves, heaters, furnaces, dryers, signs & lighting fixtures or where the acceptability has been determined by Underwriters Laboratories.
Min/Mult: 100/50
SKU: W32391626-T -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3304 Wire
UL 3304 18 AWG 07 Strand 200C 1KV – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3304 WireUL 3304 18 AWG 07 Strand 200C 1KV – Tinned Copper
UL 3304 18 AWG silicone insulated wire is constructed with solid or stranded round, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 1KV, it’s ideal for internal wiring of electronic ignitions and other similar applications in gas ranges or fuel oil burner systems, appliances.
Min/Mult: 100/50
SKU: W33041807-T