Hook-up & Lead Wire
Showing 33–49 of 49 results
-
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1429 Wire
UL 1429 22 AWG 19 Strand 80C 150V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1429 WireUL 1429 22 AWG 19 Strand 80C 150V – Tinned Copper
UL 1429 22 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 80°C maximum temperature and 150V rating, it’s ideal for use in control panels, computers, appliances and electronics.
Min/Mult: 100/50
SKU: W14292219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1429 Wire
UL 1429 24 AWG 07 Strand 80C 150V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1429 WireUL 1429 24 AWG 07 Strand 80C 150V – Tinned Copper
UL 1429 24 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 80°C maximum temperature and 150V rating, it’s ideal for use in control panels, computers, appliances and electronics.
Min/Mult: 100/50
SKU: W14292407-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 14 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 14 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 14 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14301419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 22 AWG 07 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 22 AWG 07 Strand 105C 300V – Tinned Copper
UL 1430 22 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14302207-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 22 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 22 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 22 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14302219-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 Wire
UL 1430 24 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1430 WireUL 1430 24 AWG 19 Strand 105C 300V – Tinned Copper
UL 1430 24 AWG cross-linked hook-up wire is constructed with solid or stranded, and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in the internal wiring of electronic equipment, computers, business machines and appliances.
Min/Mult: 100/50
SKU: W14302419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 14 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 14 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14311419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 Wire
UL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 1431 WireUL 1431 22 AWG 19 Strand 105C 600V – Tinned Copper
UL 1431 22 AWG cross-linked hook-up wire is constructed with stranded and tinned copper conductors. Its irradiated cross-linked pvc insulation makes it heat resistant and stronger, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 600V rating, it’s ideal for use in motor leads, power tools and internal wiring of appliances.
Min/Mult: 100/50
SKU: W14312219-T -
Hook-up & Lead Wire, UL Style 1911
UL 1911 22 AWG 07 Strand 250C 25KV – Nickel Plated
UL 1911 22 AWG PFA insulated wire is constructed with solid or stranded, nickel plated conductors. Its extruded perfluoroalkoxy insulation allows it to pass the flame test. With a 260°C maximum temperature and a rated voltage of 25KV, it’s ideal for internal wiring of electronic gas ignitor system use.
Min/Mult: 100/50
SKU: W19112207-N -
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3071 Wire
UL 3071 14 AWG 07 Strand 200C 600V – Tinned Copper
Hook-up & Lead Wire, Silicone Insulated Wire, UL 3071 WireUL 3071 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3071 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal appliance wiring.
Min/Mult: 100/50
SKU: W30711407-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3266 Wire
UL 3266 22 AWG 07 Strand 125C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3266 WireUL 3266 22 AWG 07 Strand 125C 300V – Tinned Copper
UL 3266 22 AWG cross-linked hook-up wire is constructed with stranded or solid, tinned copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the flame test. With an 125°C maximum temperature and 300V rating, it’s ideal for use in internal wiring of appliances, computers test, equipment, business machines and other office and control equipments.
Min/Mult: 100/50
SKU: W32662207-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3317 Wire
UL 3317 14 AWG 19 Strand 105C 300V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3317 WireUL 3317 14 AWG 19 Strand 105C 300V – Tinned Copper
UL 3317 14 AWG cross-linked hook-up wire is constructed with stranded or solid, tinned copper conductors. Its irradiated cross-linked pvc insulation makes it oil, gasoline and impact resistant, allowing it to pass the VW-1 flame test. With an 105°C maximum temperature and 300V rating, it’s ideal for use in internal wiring of appliances, computers, electronic equipment and business machines.
Min/Mult: 100/50
SKU: W33171419-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 14 AWG 41 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 14 AWG 41 Strand 150C 600V – Tinned Copper
UL 3321 14 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33211441-T -
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 Wire
UL 3321 22 AWG 07 Strand 150C 600V – Tinned Copper
Cross-Linked Hook-Up Wire, Hook-up & Lead Wire, UL 3321 WireUL 3321 22 AWG 07 Strand 150C 600V – Tinned Copper
UL 3321 22 AWG cross-linked hook-up wire is constructed with stranded, tinned copper conductors. Its tough irradiated cross-linked pvc insulation makes it heat and impact resistant, allowing it to pass the CSA flame test. With an 150°C maximum temperature and 600V rating, it’s ideal for use in internal wiring of appliances, transformers, heating systems and lighting systems.
Min/Mult: 100/50
SKU: W33212207-T -
Hook-up & Lead Wire, UL 3512 Wire
UL 3512 14 AWG 07 Strand 200C 600V – Tinned Copper
UL 3512 14 AWG silicone insulated wire is constructed with solid or stranded, tinned copper conductors. Its extruded silicone rubber or pvc insulation makes it chemical, weather, flame and moisture resistant, allowing it to pass the flame test. With a 200°C maximum temperature and a rated voltage of 600V, it’s ideal for internal wiring of appliances.
Min/Mult: 100/50
SKU: W35121407-T -
High Temperature Wire, Hook-up & Lead Wire, UL Style 5107
UL 5107 14 AWG 41 Strand 200 / 450 600V – Nickel Plated
High Temperature Wire, Hook-up & Lead Wire, UL Style 5107UL 5107 14 AWG 41 Strand 200 / 450 600V – Nickel Plated
UL 5107 ultra high temperature wire is contructed with glass-reinforced mica tape insulation and a braided fiberglass jacket for abrasian resistance. With a 450°C maximum temperature and 600 volt rating, its ideal for use in heaters, ovens and other ultra-high temperature environments.
Min/Mult: 100/50
SKU: W51071441-N -
High Temperature Wire, Hook-up & Lead Wire, UL Style 5256
UL 5256 14 AWG 41 Strand 250C 600V – Nickel Plated
High Temperature Wire, Hook-up & Lead Wire, UL Style 5256UL 5256 14 AWG 41 Strand 250C 600V – Nickel Plated
UL 5256 high temperature stranded hook-up wire has a maximum temperature of 250°C and a 600 volt rating. These properties make it ideal for use in ovens, home electric heating equipment, industrial dryers, etc.
Min/Mult: 100/50
SKU: W52561441-N